Power Connector
a
Power connector — The MPA 152 ships with the Extron 24 W PS 1220 desktop
power supply (part number 70-967-01).
ATTENTION: When the PS 1220 power supply is connected to the MPA 152, it
must not be shared with any other devices.
Power
Receptacle
DC Power Cord
Captive Screw
Connector
POWER
12V
0.6 A MAX
Amplifier
DC Power
Outputs
DO NOT USE
AC Power Cord
Tie
Wrap
Captive Screw
Connector
Power Supply
Output Cord
PS 1220
Power Supply
Figure 3. Power Connector
Connect the two-pole, 3.5 mm captive screw connector from the power supply to
the power socket on the rear panel of the MPA152, as shown above. Ensure the
connections have the correct polarity.
ATTENTION:
• AlwaysuseapowersupplysuppliedbyorspecifiedbyExtron.Useofan
unauthorizedpowersupplyvoidsallregulatorycompliancecertificationand
maycausedamagetothesupplyandtheendproduct.
• Suitableforuseinenvironmentalairspaceinaccordancewith
Section300.22.CoftheNationalElectricalCode,andSections2-128,
12-010(3)and12-100oftheCanadianElectricalCode,Part1,C22.1.
• Unlessotherwisestated,theAC/DCadaptersarenotsuitableforuseinair
handlingspacesorinwallcavities.Thepowersupplyistobelocatedwithin
thesamevicinityastheExtronAVprocessingequipmentinanordinary
location,PollutionDegree2,securedtotheequipmentrackwithinthe
dedicatedcloset,podium,ordesk.
• Theinstallationmustalwaysbeinaccordancewiththeapplicableprovisionsof
NationalElectricalCodeANSI/NFPA70andtheCanadianElectricalCode.The
powersupplyshallnotbepermanentlyfixedtobuildingstructureorsimilar
structure.
• Thelengthoftheexposedwiresinthestrippingprocessiscritical.Theideal
lengthis3/16inches(5mm).Anylongerandtheexposedwiresmaytouch,
causingashortcircuitbetweenthem.Anyshorterandthewirescanbeeasily
pulledouteveniftightlyfastenedbythecaptivescrews.
NOTE: Donottinthewires.Tinnedwiredoesnotholditsshapeandcanbecome
looseovertime.
MPA 152 • Panels and Cabling 5