DIPSWITCH SETTINGS
On the bottom of the unit are two sets of dipswitches. Dipswitch Bank #1 is used to configure
the serial ports to operate as an RS-232, or RS-422 / RS-485 physical interface. Dipswitch Bank
#2 is used to isolate the contact closure ports and to configure the CTL101 to the default baud
rate (9600). The factory default and specialized dipswitch settings are listed below:
Factory Default Settings:
Dipswitch Bank #1:
Dipswitches 1, 2, 3, 4, 5 & 6: All in "0" position
Input Port Serial Mode: RS-232, no termination
Output Port Serial Mode: RS-232, no termination