6. Configure the CS 120P for a U.S. or metric ceiling grid — For U.S. ceilings (2 feet
by 2 feet or 2 feet by 4 feet), leave intact the four tabs that are on one of the short ends
of the enclosure.
For metric ceilings (600 mm by 600 mm or 600 mm by 1200 mm), cut off the tabs.
Tabs (4)
Removable
Tabs
Figure 5. Tabs on the CS 120P
7. Remove the cover plate — Loosen (do not remove) the two screws on the cover
plate and remove it, as shown in figure 6.
Cover Plate
Figure 6. Removing the Cover Plate
8. Route the cables through the cover plate —
NOTES:
• The CS 120P is fully UL 2043 compliant only when it is used with a metal
conduit or with plenum rated cables.
• Installation of all conduits, conduit adapters, wiring, and electrical connections
must conform to all applicable building codes and local ordinances.
Using a flexible conduit:
a. Route wires through the conduit.
b. Insert the conduit into the cover plate opening using an appropriate conduit
adapter, and secure the conduit to the plate as shown below.
c. Pull the wires out of the conduit and through the cover plate.
CS 3T and CS 120P User Guide • Installation 7