User GuideFPC 5500Matrix Switcher AccessoriesFront Panel Controller68-556-06 Rev. A06 12
Extron FPC 5500 • Introduction 4NOTE: Figure 3 on page 3 shows an FPC 5500 connected directly to a FOX Matrix 14400 via a cross-over cable. The FPC
Extron FPC 5500 • Introduction 5NOTE: Figure 4 on page 4 shows an FPC 5500 connected directly to a FOX Matrix 320x via a cross-over cable. The FPC 5
Extron FPC 5500 • FPC Installation and Operation 6FPC Installation and Operation• Installation Overview• Unpacking and Assembling the Front Panel Co
Extron FPC 5500 • FPC Installation and Operation 7Unpacking and Assembling the Front Panel ControllerThe FPC 5500 is shipped fully assembled and read
Extron FPC 5500 • FPC Installation and Operation 8Bottom Panel ConnectionsAll connectors are on the bottom of the FPC 5500 (see figure 6).NOTE: The
Extron FPC 5500 • FPC Installation and Operation 9f Ethernet connector (RJ-45) — Connect one end of a Category (CAT) 5e or higher cable, terminated
Extron FPC 5500 • FPC Installation and Operation 10Cabling and RJ-45 Connector WiringIt is vital that your cable between the FPC 5500 and the matrix
Extron FPC 5500 • FPC Installation and Operation 11Front Panel Features and OperationThe remaining control for the FPC 5500 is on the front panel (se
Extron FPC 5500 • Matrix System Operation 12Matrix System Operation• Introduction• Operating the Touch Panel• Starting Up the Controller and Loggin
Extron FPC 5500 • Matrix System Operation 13Operating the Touch PanelSeveral of the FPC front panel operations require data entry, input and output s
This symbol is intended to alert the user of important operating and mainte-nance (servicing) instructions in the literature provided with the equipme
Extron FPC 5500 • Matrix System Operation 14Using the KeypadsAn on-screen keypad (see figure 13) is integrated into the I/O screens. A similar keypad
Extron FPC 5500 • Matrix System Operation 15Starting Up the Controller and Logging In and OutUse the FPC to control the matrix as follows:1. For a M
Extron FPC 5500 • Matrix System Operation 16To log on to the matrix, the FPC 5500 IP Address and Subnet Mask fields must be set to values that identi
Extron FPC 5500 • Matrix System Operation 17d. If you want to use the factory defaults, touch the Use Factory Defaults button and proceed to step 5l
Extron FPC 5500 • Matrix System Operation 188. Touch the Connect button. The FPC software autodetects the matrix system, reads its hardware configu
Extron FPC 5500 • Matrix System Operation 19NOTE: The following figures are based on a Matrix 12800 system. On a different matrix system (FOX Matrix
Extron FPC 5500 • Matrix System Operation 20Administration ScreensSetup ScreensAudio ScreenReset ScreenUser ScreensAdministration ScreensSetup Screen
Extron FPC 5500 • Matrix System Operation 21In the following procedures, access to a specific screen is described by assuming you are beginning at th
Extron FPC 5500 • Matrix System Operation 22ViewTies: input-by-output selection screenViewTies: outputs-by-input selection screenViewTies: input-by-o
Extron FPC 5500 • Matrix System Operation 23View the ties as follows (see figure 20 on page 22):1. From any screen other than the Make Ties screen,
FCC Class A NoticeThis equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rule
Extron FPC 5500 • Matrix System Operation 24Viewing Outputs Tied to a Specified Input1. If necessary, touch the View Outputs button. The most recen
Extron FPC 5500 • Matrix System Operation 25Creating TiesThere are two ways to make ties (see figure 21):• You can select an input and an individual
Extron FPC 5500 • Matrix System Operation 26Tie an input to an output as follows:1. Touch the blue User > amber I/O > green Make Ties buttons.
Extron FPC 5500 • Matrix System Operation 274. For an immediate tie, proceed to step 7.5. To add the potential tie that you have just created to a
Extron FPC 5500 • Matrix System Operation 28The FPC displays the equivalent SIS commands in the Pending Tie commands field. The example above shows a
Extron FPC 5500 • Matrix System Operation 294. Touch the green Save, Recall, or Delete button. stores the current configuration in memory. If the gl
Extron FPC 5500 • Matrix System Operation 30Save, Recall, or Delete a Room PresetSee h on figure 22 on page 29. Save, recall, or delete a room preset
Extron FPC 5500 • Matrix System Operation 31Mute ScreenThe Mute screen (see figure 23) lets you mute the audio or RGBHV or RGBS video (black screen)
Extron FPC 5500 • Matrix System Operation 32DSVP ScreenNOTE: This screen is available on Matrix 12800 systems only.You can monitor each RGBHV and RG
Extron FPC 5500 • Matrix System Operation 33Admin ScreensThe Admin family of screens include the functions that are typically reserved for or applica
Extron FPC 5500 • Matrix System Operation 34Figure 26. Status Screen for a FOX Matrix 320x SystemStatus Screen, System AreaThe System area, in the t
Extron FPC 5500 • Matrix System Operation 35Status Screen, Physical LayoutNOTE: This screen is available on FOX Matrix 14400 and 320x systems only.T
Extron FPC 5500 • Matrix System Operation 36Access the Remotes screen by touching the blue Admin > purple Status > green Remotes buttons. Upda
Extron FPC 5500 • Matrix System Operation 374. Touch the green Take button to accept the changes or touch the green Cancel button to reject the
Extron FPC 5500 • Matrix System Operation 38Hardware Address FieldThe Hardware Address (MAC) field is factory programmed on the primary controller bo
Extron FPC 5500 • Matrix System Operation 39E-Mail ScreenNOTE: Only personnel logged in as Administrators can make changes to the E-mail screen.The
Extron FPC 5500 • Matrix System Operation 40There are two levels of FPC 5500 password protection: administrator and user. Administrators have full ac
Extron FPC 5500 • Matrix System Operation 41E-mail Addressee FieldsNOTE: Only personnel logged in as Administrators can edit the E-Mail Addressee fi
Extron FPC 5500 • Matrix System Operation 42File Manager ScreenThe File Manager screen (see figure 32) is a reporting screen only, with no active fun
Extron FPC 5500 • Matrix System Operation 43Function Keys ScreenNOTE: Only personnel logged in as Administrators can set User Function keys.The Func
vExtron FPC 5500 • ContentsContentsIntroduction... 1About this Guide ...
Extron FPC 5500 • Matrix System Operation 445. Use a pencil eraser or other small, soft object to touch the None, Momentary, or Toggle radio button
Extron FPC 5500 • Matrix System Operation 45I/O Physical Connectors ScreenThe I/O Physical Connectors screen (see figure 34) shows how the matrix sys
Extron FPC 5500 • FPC Installation and Operation 46Naming Inputs and OutputsNOTE: Only personnel logged in as Administrators can name video and audi
Extron FPC 5500 • Matrix System Operation 47Setup ScreensThe Setup family of screens include the functions that are typically done when initially set
Extron FPC 5500 • Matrix System Operation 48Audio ScreenNOTES: • Only personnel logged in as administrators can set the audio level.• The Audio scr
Extron FPC 5500 • Matrix System Operation 49Reset ScreenNOTES: Personnel logged in as users can reset all current ties and all mutes. All other sele
Extron FPC 5500 • Matrix System Operation 50Subnetting — A PrimerIt is not the purpose of this manual to describe TCP/IP protocol in detail. However,
Extron FPC 5500 • Specifications 51ReferenceInformationSpecifications Control connection to matrixConnectors ... 1
Extron Headquarters+1.800.633.9876 (Inside USA/Canada Only)Extron USA - West Extron USA - East +1.714.491.1500 +1.919.850.1000 +1.714.491.1517 FAX +
Extron Headquarters+1.800.633.9876 (Inside USA/Canada Only)Extron USA - West Extron USA - East +1.714.491.1500 +1.919.850.1000 +1.714.491.1517 FAX +
Extron FPC 5500 • Contents vi
Extron FPC 5500 • Introduction 1Introduction• About this Guide• About the FPC 5500 Front Panel Controller• About the Matrix 12800 System• About th
Extron FPC 5500 • Introduction 2About the Matrix 12800 SystemThe Matrix 12800 system (see figure 2) is made up of a series of matrix switcher Basic M
Extron FPC 5500 • Introduction 3The Matrix 12800 Series includes:• Wideband video switcher BME — A rack-mountable 10U switcher that routes video (re
Comentarios a estos manuales