MKP 3000 Series • SIS
™
Operation
MKP 3000 Series • SIS
™
Operation
SIS
™
Operation, cont’d
4-9
X22
= Daylight Savings Time 0 = Daylight Savings Time off/ignore
1 = Daylight Savings Time on
(northern hemisphere)
2 = Daylight Savings Time on
(Europe)
3 = Daylight Savings Time on (Brazil)
X23
= IP address ###.###.###.###
X24
= Hardware (MAC) address ##-##-##-##-##-##
X25
= Connection priority 0 = Primary
1 = Secondary
X26
= Password 12 digits, alphanumeric
The following characters are invalid in passwords:
{space} + ~ @ = ‘ [ ] { } < > ’ “ ; : | \ and ?.
X27
= Web page priority 0 = Internal (default on power up)
1 = User
X28
= Executive mode 0 = Administrator mode (panel
unlocked)
1 = User mode
2 = Panel locked
X29
= Tie mode 0 = Matrix mode
1 = Input-only mode
4-8
Command/response table for MKP SIS commands
Command ASCII Command Response Additional description
(host to MKP) (MKP to host)
Front panel security lockout (executive mode)
Panel locked mode 2x Exe2 Lock front panel.
User mode 1x Exe1
Enable only input, output, preset, and volume
selection from the front panel.
Administrator mode 0x Exe0
Unlock front panel.
View front panel lock status x
X28
Show front panel lock status. For
X28
:
0 = Administrator mode (panel unlocked).
1 = User mode.
2 = Panel locked.
Pass-through (RS-232 port redirect)
Configure redirect mode
Esc
X2
*
X3
*
X4
*
X5
CD
Cpn
X2
• Ccd
X3
,
,
X5
Turn redirect mode on.
Example:
Esc
1*2*50*10D*CD Cpn01• Ccd00002,00050,00000L
Redirect port 1 to port 2. Wait 500 ms for response.
The “L” or “D” delimiter in value
X5
is case sensitive and must be uppercase.
Disable redirect
Esc
X2
* 0CD Cpn
X2
• Ccd00000,00000,00000L
View redirect
Esc
X2
CD
X3
,
X4
,
X5
View redirect mode on/off status.
Information requests
Information request I MKP • 3000 • LCD • KEYPAD or MKP • 3000 • LCD
Request for part number N 60-7xx-00 MKP 3000 and MKP 3000 MAAP without MKP 10:
60-708-00
MKP 3000 L: 60-709-00
MKP 3000 MAAP with MKP 10: 60-710-00
Comentarios a estos manuales