MLA-VC10 • Configuration and Operation
3-9
8. Select "Relay 1" in the "Device" pane (see figure 3-12).
9. Select "Close" in the "Action Commands" pane.
10. Click the Apply Action button.
Select Relay 1.
Select Close
Click Apply Action.
Figure 3-12 — Monitored Conditions Wizard (steps
8-10)
11. Click Done, which will close the Monitored Conditions
Wizard.
This monitor mutes the TOA amplifier when the MLA VC10
volume is turned to 0.
12. Add a new monitor to unmute the TOA amplifier (see steps 2
and 3).
13. Select "Volume
(Discrete): range
(0.100,1)" and choose
the options "Is greater
or equal" and "1.0" (see
the figure at right and steps 5 and 6).
14. Apply the action and close the Wizard (see steps 7-12).
This monitor unmutes the TOA amplifier when the volume
on the MLA VC10 is turned to 1 or more.
When the Wizard is completed, Global Configurator shows
a list of monitored conditions and actions in the "Monitored
Conditions" pane (see figure 3-13 on the next page).