Extron • SENTOSA
xi
LQ & LANCIA
xi
LD • User’s Manual
RS-232/REMOTE Control
Page 3-2
COMMAND/RESPONSE TABLE
Definitions and Abbreviations:
= CR/LF · = space = 1 or 2 (Input #) = 1 – 127 = 0 or 1, 0 = OFF, 1 = ON
= Input type (T), 0 = no input, 1 = NTSC 3.58, 2 = PAL, 3 = NTSC 4.43, 4 = SECAM = Software version x.xx = 1 – 63
COMMAND RESPONSE Example Commands and Responses
ASCII HEX to Host Command Description Command Response Action/Explanation
!
h
21
h
C Select input channel (C) 2! C2 Select Input channel #2
F7C
h
Frz1 Freeze ON (ASCII F or | accepted) F Frz1 Freeze (Frame) Video
f7E
h
Frz0 Freeze OFF (ASCII f or ~ accepted) f Frz0 Release Freeze Mode
i69
h
(Same as I below) Information request i C2·T1·Col65·Tin70·Con100·Hph39·Frz0
I49
h
C·T·Col ·Tin ·Con ·Hph ·Frz IC2·T1·Col65·Tin70·Con100·Hph39·Frz0
n6E
h
(Same as N below) Request for part number n N60-213-01 60-213-01 = Lancia
N4E
h
N60-213-01 Request for part number N N60-229-01 60-229-01 = Sentosa
q71
h
(Same as Q below) Query software version q QVER·1.23 (1.23 is example only)
Q51
h
QVER· Query software version Q QVER·1.23 Software version 1.23
C
h
43
h
Col Set color value (Col) to 25C Col25 Color value to 25
{C 7B
h
43
h
Col Increment color value {C Col26 Color value + 1
}C 7D
h
43
h
Col Decrement color value }C Col25 Color value – 1
T
h
54
h
Tin Set tint value (Tin) to 32T Tin32 Tint value to 32
{T 7B
h
54
h
Tin Increment tint value {T Tin33 Tint value + 1
}T 7D
h
54
h
Tin Decrement tint value }T Tin32 Tint value – 1
^
h
5E
h
Con Set contrast value (Con)to 99^ Con99 Contrast value to 99
{^ 7B
h
5E
h
Con Increment contrast value {^ Con100 Contrast value + 1
}^ 7D
h
5E
h
Con Decrement contrast value }^ Con99 Contrast value – 1
H
h
48
h
Hph Set horizontal phase value (Hph) to 39H Hph39 Set H. Phase Value to 39
{H 7B
h
48
h
Hph Increment Hph value {H Hph40 Horiz. Phase Value + 1
}H 7D
h
48
h
Hph Decrement Hph value }H Hph39 Horiz. Phase Value – 1
Exx Error Response see “Error Responses” – next page