Dimensions, Templates, Replacements, Upgrades, cont’d
MediaLink Controllers • Dimensions, Templates, Replacements, and UpgradesB-6
A
B
C D EA
B C
IR
Display/Source Control
Extron Switcher Control
Relays IR/RCM
RS-232
DE
A
B C
A
B
D
1A
1B 2A
2B 3A
3B
1
2
3 4
5
6
Tally Out
MLS
/Power
33-644-01 A
07 01
Printed in the
USA
Align Notches
Locating the firmware IC chip, and aligning the PLCC chip puller tool
with firmware chip slots
5. After you are electrically grounded, align the hooks of a PLCC IC puller tool
with the slots located in opposite ends of the firmware chip.
6. Insert the hooks into the slots, and squeeze the tool gently to grasp the chip.
7. Pull the chip straight out of the socket, and set it aside.
8. Align the notch on one end of the new firmware IC chip with the socket’s
notch indicator (in the same orientation as the old chip).
9. Gently but firmly press the chip into place in the socket.
10. Replace the MLC’s rear cover, and fasten it with the screws and hex standoffs
that were removed in step 3.
11. Re-mount the MLC, and reconnect the power supply to the power source.