Contact Closure Remote Control
For contact closure, connect a contact closure remote control device to the contact closure
female 5-pole captive screw connector of the front panel. Various AAP devices and cable
assemblies are also available from Extron to provide remote contact closure capability.
The pin assignments for the contact closure connector of the RGB 580xi are shown in the
following table.
Pin Contact Closure Description
A
Contact closure + Contact closure + circuit
B
Contact closure - Contact closure - circuit
C +5 V
+5 V source for powering AAP devices
D Gnd
Signal ground for powering AAP devices
E -5V
-5 V source for powering AAP devices
RGB 580xi • Connection and Conguration 20