Remote Control
e
Remote input connector — This 3-pin, captive screw connector
allows a wall-mounted audio controller or MediaLink product to
control volume and mute levels remotely.
Wiring for remote control
Options for remote control include the Extron VC50, VCM100AAP, VCM100MAAP,
VCM 200 series, and MLAVC10 Plus. For information about part numbers, see the list of
Optional Accessories on page 12. Third party 10k potentiometer volume controllers can
also be connected to this port.
Figure 5 and the instructions below, show the wiring for the VCM 100 MAAP. Wiring other
remote control connectors is similar.
GND (Pin 3)
Volume Pot
10K Ohms
2K
Vol/Mute
(Pin 2)
10 V (Pin 1)
Mute
Switch
REMOTE
Figure 5. Remote Control Wiring
• Pin 1 is 10 VDC reference voltage.
• Pin 2 (Vol/Mute) has two functions:
a. It can be used as a variable voltage input between 0 and 10 VDC, with 0 V giving
full attenuation and 10 V giving maximum volume.
b. It can be used for remote control muting. Sound is muted while the mute pin is
shorted to ground.
• Pin 3 is ground.
NOTE: All nominal levels are at ± 10%.
Controlling multiple ampliers with one volume controller
Several MPA 152 units can be daisy-chained so that one volume controller can
simultaneously regulate the volume of all the amplifiers.
NOTES:
• Asadditionalamplifiersareaddedtothedaisychain,thesensitivityofthe
volumepotentiometerwillchange.Themaximumvolumelevel(fullyclockwise)
willnotbeaffected.Howevertheeffectivenessoftheminimumvolumelevel
(fullycounterclockwise)inreducingthevolumetoinaudiblelevelsdecreasesas
moreamplifiersareaddedtothedaisychain.
• WhenmorethantwoMPAsareattachedtothechain,soundmaybeginto
beheardevenifthelevelshavebeensettotheirlowest.Themutingofthe
outputhowevercanberemediedwithacontactclosurebuttonattached
betweentheVol/MuteandGroundpinofthefirstMPAinthechain.