Cable Retraction System • Before Getting Started 6
For new Installations:
Choose the optimal mounting location for the CableCubby enclosure. The final location may
require some adjustment depending upon under-table clearances required for the retraction
system. Once the location has been determined, follow the instructions provided with the
enclosure for mounting and installing a power module and AAPs.
For retrofit installations:
For most retrofit installations, the Cable Cubby enclosure does not require removal.
Disconnect all power to the Cable Cubby before retraction system installation.
CC300, CC600, CC800 Enclosure Clearances
The following diagrams show the clearance dimensions required for mounting a retractor
system in a CC300, CC600, or CC800 enclosure.
Horizontal Mounting Clearance
CC300/600/800
XL Models
9.0"
(22.9 cm)
15.7"
(39.9 cm)
16.7"
(42.5 cm)
3.0"
(7.6 cm)
9.0"
(22.9 cm)
21.7"
(55.0 cm)
23.0"
(58.5 cm)
3.0"
(7.6 cm)
See
Table A
Figure 5. Vertical and Horizontal Clearance Requirements (CC 800 shown)
1.9" (4.8 cm)
23.3"
(59.2 cm)
1.9" (4.8 cm)
29.3"
(74.4 cm)
Vertical Mounting Clearance
CC300/600/800
XL Models
See
Table B
Enclosure Model Dimension
CC 200 6.2 inches (15.8 cm)
CC 300/600/800 6.4 inches (16.3 cm)
Table A. Vertical Dimension from Table Top To Pigtail
(Horizonal Mounting)
Enclosure Model Dimension
CC 200 9.5 inches (24.1 cm)
CC 300/600/800 9.5 inches (24.1 cm)
Table B. Vertical Dimension from Table Top To Pigtail
(Vertical Mounting)