WindoWall Pro Series • Remote Configuration and Control 40
Command and Response Table for IP SIS Commands
Command
ASCII (Telnet)
(Host to Processor)
URL Encoded (Web)
(Host to Processor)
Response
(Processor to Host)
Additional Description
Bi-directional Serial Data Port
Send data string
E
X10!
*
X10(
*
X11)
*
X11!
RS
}
X11)
W
X10!
%2A
X10!
%2A
X11)
%2A
X11!
RS
|
X10@
{Response from command}
]
Example:
E
05 * 4 * 7 * 3L RS
}
<data>•
W 05 %2A 4 %2A 7 %2A 3L RS
|
{data}
{Response from command}
NOTES:
X10!
= Port number (01-99)
X10(
= Time in tens of milliseconds that the WindoWall Pro will wait until receipt of the first response character
before terminating the command. Default = 10 = 10 ms. Max. = 32767.
X11)
= Time in tens of milliseconds that the WindoWall Pro will wait between characters being received via a serial
port before terminating the current command or receive operation. Default = 20 = 20 ms. Max. = 32767.
X11!
= Message length #L or #D. The letter parameter is case sensitive (requires capital D or capital L).
L = Length of the message to be received.
D = Delimiter value. A delimiter of ASCII 0A = 10D.
# = Byte count (for L) or a single ASCII character expressed in decimal form (for D).
The byte count # can be 0-32767. Default = 0.
The ASCII decimal # can be 0-00255. Default = the byte count.
A 3-byte length = 3L. The response includes leading zeros.
X10@
= Command data section. For web encoding for
X10@
, be sure to convert non-alphanumeric characters to hex
numbers.
The *
X10(
*
X11)
*
X11!
sequence is optional. If
X10(
and
X11)
are not specified, the default values are used.
Configure serial
port parameters
24
E
X10!
*
X11^
,
X11&
,
X11*
,
X11(
CP
}
W
X10!
%2A
X11^
%2A
X11&
%2A
X11*
%2A
X11(
CP
|
Cpn
X10!
•Ccp
X11^
,
X11&
,
X11*
,
X11(
CP
]
Set baud rate
X11^
, parity
X11&
, data bits
X11*
, and
stop bits
X11(
for port
X10!
.
X11^
= 2400, 4800, 9600,
19200, 38400, or
115200.
X11&
= odd, even, none,
mark, or space.
(Only the first letter is
required.)
X11*
= 7 or 8
X11(
= 1 or 2
View serial port
parameters
E
X10!
CP
}
W
X10!
CP
| X11^
,
X11&
,
X11*
,
X11(
CP
]
Configure mode
24
E
1 *
X12)
CY
}
W 1 %2A
X12)
CY
|
Cpn1•Cty
X12)]
Select serial mode
X12)
for
the rear panel RS-232/422
port. For
X12):
0 = RS-232
1 = RS-422
View serial mode
E
X10!
CY
}
W
X10!
CY
| X12)
]
View current port mode.