Timeout
Pauses of 10 seconds or longer between command ASCII characters result in a timeout. The
command operation is aborted with no other indication.
Using the Command and Response Table
The Command and Response Table for SIS Commands is on page 10. Lower case letters
are acceptable in the command field.
Symbols are used throughout the table to represent
variables in the command/response fields. Command and response examples are shown
throughout the table. The following ASCII to HEX conversion table (see figure 6) is for use
with the command and response table.
ASCII to HEX Conversion Table
Figure 6. ASCII to HEX Conversion Table
Symbol Definitions
The following symbols (variables) are used in the command and response table. The
symbols represent variables in the unit-initiated messages and the command and response
table fields.
] = CR/LF (carriage return/line feed)
= space
X! = Output 1 through 8
X@ = Mute status 0 = off (unmuted)
1 = on (muted)
X# = Firmware version Vx.xx
X$ = Transceiver module status 00000000 = no light input
10000000 = light input
X% = Temperature nnnF = whole degree Fahrenheit
X^ = Transceiver module status 0 = no module installed
1 = multimode
2 = singlemode
Extron FOX DA8 • Remote Control 9