HDXP Plus Series Switchers • Operation 15
Configuration Port (HDXP 3232 Only)
c
Config port (HDXP 3232 only) — This RS-232 port is an alternative to the
RS232/RS422 connector on the HDXP rear panel (see Rear Panels and Cabling
on page 6 for a description). This port (RS-232 only) can be used for system
configuration and control via SIS commands or the Windows-based control software.
For information on connecting to this port, see RS-232 and RS-422 Remote
Connections on page 11.
Control Buttons
d
Enter button — The Enter button has three primary functions (
❏
) and five
secondary (
•
) functions:
❏
Saves changes that you make on the front panel. To create a simple
configuration:
a. Specify a Matrix connection (see I/O Buttons on page 16 [
h
and
i
]).
b. Press the desired input button (
a
).
c. Press the desired output buttons (
b
).
d. Press the Enter button.
❏ Indicates that a potential tie has been created but not saved.
❏ Indicates that a global preset has been selected to be saved or recalled but that
the preset action has not been accomplished.
• In I/O Grouping mode, selects group 1 (see I/O Grouping on page 26).
• In I/O grouping mode, indicates that group 1 is selected (see I/O Grouping).
• Selects the RS-232 or RS-422 protocol and baud rate (see Selecting the
RS-232 or RS-422 Protocol and Baud Rate on page 36).
e
Preset button — The Preset button has two primary functions (
❏
) and five
secondary (
•
) functions:
❏ Places the switcher in preset saving mode to save a configuration as a preset,
and in preset recalling mode to activate a previously-defined preset.
❏ Blinks when preset saving mode is active, and lights steadily when preset recalling
mode is active.
• In I/O grouping mode, selects group 2 (see I/O Grouping).
• In I/O grouping mode, indicates that group 2 is selected (see I/O Grouping).
• Selects the RS-232 or RS-422 protocol and baud rate (see Selecting the
RS-232 or RS-422 Protocol and Baud Rate).