Extron-electronics MLC 226 IP Series Installation Manual de usuario Pagina 90

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 164
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 89
SIS
Programming and Control, cont’d
MLC 226 IP Series • SIS Programming and Control
5-12
PRELIMINARY
Command/response table for SIS commands (continued)
Command ASCII (Telnet)
(host to switcher)
URL Encoded (Web)
(host to switcher)
Response
(switcher to host)
Additional description
View +5 V IR receiver port
voltage
13S 13S
+
X20^]
View +3.3 V IP Link/FPGA
voltage
14S 14S
+
X20^]
View +1.5 V FPGA voltage 15S 15S
+
X20^]
View -10 V IR/Serial bus voltage 16S 16S
-
X20^]
Display the operating voltage for the IR/
Serial and projector ports.
View internal temperature status 20S 20S
X20&]
Display the internal operating temperature.
X20&
= temperature in degrees Celsius (the
response is 3 digits including leading zeros).
Vista de pagina 89
1 2 ... 85 86 87 88 89 90 91 92 93 94 95 ... 163 164

Comentarios a estos manuales

Sin comentarios