Configuration
The DA configuration switch selects any of the three configurations as identified in figure 5,
below.
NOTE: When you change the position of the DA configuration switch, the reclocking
feature returns to the default setting of 4.25 Gbps on all inputs. See the
Reclocking information in the SIS commands section and FOX Extenders
section to set the reclocking feature to the desired values.
FOX DA8 Plus
100-240V 0.3A
OPTICAL OUTPUTS
A BCD
OUTIN
1
OUT IN
3
OUT IN
5
OUT IN
7
(1)1x8
(2)1x4
(4)1x2
50/60 Hz
RS-232
Tx Rx
OUT N/A
4
OUT N/A
6
OUT N/A
8
OUT N/A
2
FOX DA8 Plus
100-240V 0.3A
OPTICAL OUTPUTS
A B C D
OUTIN
1
OUTIN
3
OUTIN
5
OUT IN
7
(1)1x8
(2)1x4
(4)1x2
50/60 Hz
RS-232
Tx Rx
OUT N/A
4
OUT N/A
6
OUT N/A
8
OUT N/A
2
FOX DA8 Plus
100-240V 0.3A
OPTICAL OUTPUTS
ABCD
OUTIN
1
OUTIN
3
OUTIN
5
OUTIN
7
(1)1x8
(2)1x4
(4)1x2
50/60 Hz
RS-232
Tx Rx
OUTN/A
4
OUTN/A
6
OUTN/A
8
OUTN/A
2
Rx
Tx
Tx Tx
Tx TxTx Tx
Rx Rx Rx Rx Rx Rx Rx
Rx Rx Rx Rx Rx Rx Rx Rx
Rx Rx Rx Rx Rx Rx Rx Rx
CGroup: A
Group: ACDB
(1)1x8
(2)1x4
(4)1x2
(1)1x8
(2)1x4
(4)1x2
(1)1x8
(2)1x4
(4)1x2
One 8-output DA
Not grouped.
Single input on input 1
Outputs 1 through 8
Two 4-output DAs
Group A:
Input 1
Outputs 1 through 4
Group C:
Input 5
Outputs 5 through 8
Four 2-output DAs
Group A:
Input 1
Outputs 1 and 2
Group B:
Input 3
Outputs 3 and 4
Group C:
Input 5
Outputs 5 and 6
Group D:
Input 7
Outputs 7 and 8
Group C:
Input 5
Outputs 5 and 6
Group D:
Input 7
Outputs 7 and 8
Figure 5. DA Configurations Based on Switch Position