Extron-electronics FOX DA8 Plus User Guide Manual de usuario Pagina 15

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 29
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 14
Remote Control
The topics covered in this section are:
Remote Control Ports
Simple Instruction Set Control
FOX Extenders Program
Remote Control Ports
The FOX DA8 Plus has two ports that can be connected to a host device such as a computer
running the Extron DataViewer utility or the HyperTerminal utility, an RS-232 capable PDA, or
a control system. These ports make remote control of the DA possible. The ports are:
The rear panel RS-232 port — This is a 3-pole captive screw connector (item e on
page 6). The protocol for this port is as follows:
9600 baud no parity 8 data bits
1 stop bit no flow control
The front panel Config(uration) port — This is a mini USB B port and requires the
DataViewer utility (version 2.0 or newer).
NOTE: Before you use the USB port for the first time, you need to install and
activate the USB driver on your computer. The simplest way to do this is to
install version 1.5 or newer of the FOX Extenders Program and then run the
Found New Hardware Wizard (see “Installing the Software“ on page 12
and “Activating a USB port for the first time“ on page 13.
FOX DA8 Plus • Remote Control 9
Vista de pagina 14
1 2 ... 10 11 12 13 14 15 16 17 18 19 20 ... 28 29

Comentarios a estos manuales

Sin comentarios