Command
ASCII Command
(host to unit)
Response
(unit to host)
Additional Description
IP Setup Commands
Set unit name
E X11@
CN
}
Ipn
•
X11@
]
Set the name of the unit.
Set unit name to
factory default
E
•
CN
}
Ipn
•
X14(
]
Sets the name of the unit to the
factory default.
View unit name
E
CN
} X11@
]
View the name of the unit.
Set date / time
E X11#
CT
}
Ipt
•
X11#
]
Set the date and time.
View date / time
E
CT
} X11#
]
View the date and time.
Set GMT offset
E X10#
CZ
}
Ipz
X10#
]
Set the Greenwich Mean Time
(GMT) offset value.
View GMT offset
E
CZ
} X10#
]
View the Greenwich Mean
Time (GMT) offset value.
Set daylight savings
time
E X13$
CX
}
Ipx
X13$
]
Set daylight savings time.
View daylight savings
time
E
CX
} X13$
]
View the daylight savings time
setting.
Set DHCP on
E
1DH
}
Idh1
]
Sets DHCP to on.
Set DHCP off
E
0DH
}
Idh0
]
Sets DHCP to off and resets
the IP address of the
SME100 to factory default
(192.168.254.254) if DHCP
was previously on.
View DHCP mode
E
DH
} X1)
]
View the DHCP mode setting.
Set IP address
E X11$
CI
}
Ipi
•
X11$
]
Set the IP address of the unit.
View IP address
E
CI
} X11$
]
View the IP address of the unit.
View hardware MAC
address
E
CH
} X11*
]
In verbose mode:
Iph
•
X11*
]
View the hardware MAC
address of the unit.
Set subnet mask
E X11(
CS
}
Ips
•
X11(
]
Set the subnet mask of the
unit.
View subnet mask
E
CS
} X11(
]
View the subnet mask of the
unit.
Set gateway IP
address
E X11$
CG
}
Ipg
•
X11$
]
Set the gateway IP address.
View gateway IP
address
E
CG
} X11$
]
View the gateway IP address.
NOTES:
X1) = Off (disable) and On (enable) 0 = Off or disable, 1 = On or enable
X10# = GMT offset value -12:00 through 14:00; represents GMT offset (HH:MM)
X11@ = Unit name Text string up to 24 characters (see Unit name on page 130)
X11# = Set / view local time Format to set: MM / DD / YY - HH : MM : SS (use the 24-hour clock)
X11$ = IP address (xxx.xxx.xxx.xxx) Factory default IP address = 192.168.254.254
Factory default gateway IP address = 0.0.0.0
X11* = Hardware MAC address 00 - 05 - A6 - xx - xx - xx
X11( = Subnet mask Factory default subnet mask = 255.255.0.0
X13$ = Daylight savings time 0 through 3 (see Daylight savings time on page 132)
X14( = Default name Shows the default name of the unit using the model name and the last
three pairs of the MAC address (example: SME - 100 - HD / SD - 00 - 02 - 3D)
SME 100 • Remote Communication and Control 147