Backing Up the SME100 Using Backup All
If a Backup All has never been done, or to do a routine backup of both the IP and Box
configuration files:
1. Connect the SME100 (see "Rear Panel Features" on page 12).
2. Open a web-browser and enter the IP address of the SME100 (see "Accessing the
Web-based User Interface" on page 47).
3. Go to the File Management Tab (see figure 68 on page 74).
4. Select the Backup/Restore link on the left sidebar of the File Management page.
5. Under Backup select Backup All (item
a
in figure 68 on page 74).
NOTE: Two files, IP.CFG and BOX.CFG are placed in the nortxe-backup directory.
Prior to the first backup, the nortxe-backup directory does not exist. The
SME100 creates it, then places the two files in it.
Backup of the current SME100 configuration is complete. The two files
(IP.CFG and BOX.CFG) can be used at any time to return the SME100 to this state.
At this time, copies of the two files (IP.CFG and BOX.CFG) should be saved to a remote
location for future use (see "Saving Files" on page72).
Restoring Config Files from the Backup
Once a Backup All has been completed, the two backup files exist in the SME100
nortxe-backup directory on the File Management page. To restore the IP.CFG or BOX.CFG
files after making undesired changes, or to return the SME100 to a known state:
1. Connect the SME100 (see "Rear Panel Features" on page 12).
2. Open a web browser and enter the IP address of the SME100 (see "Accessing the
Web-based User Interface" on page 47).
3. Select the File Management Tab (see figure 68 on page 74).
4. Select the Backup/Restore link on the left sidebar of the File Management page.
5. Under Restore there are two options to restore either the IP.CFG (
b
in figure 68 on
page 74) or BOX.CFG (
c
in figure 66). Select the config file to restore. The restore
program starts automatically.
6. Once completed, the program redirects to the Live View page.
NOTE: When restoring both configuration files, always do the BOX.CFG first
followed by the IP.CFG. That prevents having to change the IP settings until
after both configuration files have been restored.
Restoring the Configuration from Another SME100
A BOX.CFG file from another SME100 can be used to restore your SME100 to a known
configuration using the following instructions.
NOTES:
Only use a donor SME100 with the same firmware version.
In the following procedures, the donor SME100 is referred to as device D; the
SME100 that will be restored with the donor configuration is referred to as
device A.