On the donor SME100 (device D):
1. Complete the procedure "Backing Up the SME100 using Backup All" on the previous
page. If Backup All has already been completed, go to step 2.
2. Open a web-browser. Enter the IP address of device D, then press <Enter>.
3. Go to the File Management Tab (see figure 68 on page 74).
4. Select the File Management link on the left sidebar of the File Management page.
5. Select the nortxe-backup directory, then select the BOX.CFG file.
6. Save the BOX.CFG file to a remote location such as a flash drive or network location (see
"Saving Files" on page72).
On the SME100 to be restored (device A):
7. Complete the procedure "Backing Up the SME100 using Backup All" .
If Backup All has already been completed, go to step 8.
8. In the web browser address line, enter the IP address of device A and press <Enter>.
9. Go to the File Management Tab.
10. Select the File Management link on the left sidebar of the File Management page.
11. Click the nortxe-backup directory
12. Using the SME100 file management page, locate and select the BOX.CFG file from
device D saved in step6.
13. Select Upload. When asked to replace the current file, choose Yes.
14. Once the file is uploaded, select Backup/Restore from the left hand column of the File
Management page.
15. Under Restore, select Box-Specific. The restore begins automatically.
16. When the restore has completed, the SME100 automatically reboots and the browser
returns to the Live View page.
The restore is complete. Your box now has the same configuration as the donor box.
NOTE: The IP.CFG file is provided as a means of restoring each box to a known
IP configuration. Although an IP.CFG file from one box can be uploaded to
another, it is not recommended. The file is meant as a backup for its specific
box to resolve network issues.
If there is a need to upload an IP.CFG file from a donor box, your box will
initially have the IP address of the donor box. Before communicating with your
box, ensure the donor box is either disconnected from the network or its power
removed; then use the donor IP address to communicate with your box. Once
connected to your box, change its IP address to the desired one.
To reference the IP settings of the donor box, look at its front panel display.
SME100 • Web-based User Interface Operation 76