Backup / Restore Page
The File Management tab also contains a backup and restore page, accessed by clicking on
the Backup/Restore link on the left sidebar (see figure 68).
1
2
3
Backup
Restore
Backup All
IP Config
Box-specific
- Save IP configuration (ip.cfg) and box-specific parameters (box.cfg)
- Restore IP configuration
- Restore box-specific parameters
Backup files are stored in directory “/nortxe-backup”.
Backup / Restore
Backup/Restore
Figure 68. Backup / Restore Page
NOTE: FTP provides an alternative method to accessing and managing the backup files
of the SME100. See "Managing Files Using FTP" on page 73 for information.
The current configuration settings of connected devices can be saved and recalled using the
Backup / Restore page. The backup is saved as two files; IP config and box-specific. Both
files are saved when executing a Backup All, but each file must be restored individually. All
backups use the same filenames, so a current Backup All overwrites previous files.
The Backup / Restore page contains the following options:
a
(Backup) Backup All — Click this button to save all IP configuration and box specific
parameters from the connected SME100. A folder is automatically created on the File
Management page called nortxe-backup and contains the ip.cfg and box.cfg files.
These two files are used with the Restore IP Config (
b
) and
Restore Box-specific (
c
) buttons when restoring configuration settings.
b
(Restore) IP Config — Click this button to restore the IP configuration that was last
saved using the Backup All button above.
NOTE: If the SME100 was not backed up previously, or if there is not an ip.cfg
file stored in the nortxe-backup folder, the Restore IP Config button will not
be able to restore the IP configuration for the SME100.
c
(Restore) Box-specific — Click this button to restore the box specific parameters last
saved using the Backup All button above.
NOTE: If the SME100 was not backed up previously, or if there is not a box.cfg
file stored in the nortxe-backup folder, the Restore Box-specific button will
not be able to restore the box specific parameters for the SME100.
When the device is new or recently reset, there will be no backup files. A backup will need
to be completed before a restore can be accomplished. The following sections provide
procedures for using these buttons appropriately.
SME100 • Web-based User Interface Operation 74